Chapter 2.1 - Fuels and Combustion

8 pages, 47 questions, 1 questions with responses, 1 total responses,    0    0
bee_energy
  
+Fave Message
 Home > bee_energy >   F Also featured on: vaish_khan

Formatting page ...

Question bank for Energy Managers & Energy Auditors Chapter 2.1: Fuels and Combustion Part I: Objective type Questions and Answers 1. The unit of Density in SI system is ___. a) kg/m2 2. b) kgf/m3 b) Hydrometer c) Bomb calorimeter d) none of the above The unit of specific gravity in SI system is ___________ a) N/m3 4. d) kg/m3 Name the instrument used for the measurement of specific gravity of liquid fuels a) Gravimeter 3. c) kg/m2 b) kgf/m3 c) kg/m2 d) no unit If the liquid fuel is highly viscous, the action required for proper burning in boiler is ___. a) Pre-heating b) cooling c) mixing d) vapourising 5. In case of net calorific value (NCV) of any fuel, it assumes that water leaves with the combustion products with fully being condensed . State True or False 6. Identify the fuel which has the highest specific gravity. a) furnace oil 7. b) LSHS c) LDO d) HSD In case of fuel oils, choose the correct answer from the following, which describes the relation between specific heat and specific gravity a) lighter oil have higher specific heat c) lighter oil have lower specific heat 8. b) heavier oil have lower specific heat d) none of the above Viscosity of a liquid fluid is very much dependent on a) pressure c) temperature 9. b) pipe size d) colour Presence of sulphur in the boiler fuel leads to a) corrosion b) erosion c) low heat transfer d) none of the above 10. For complete combustion of every kg of FO firing, the approximate theoretical quantity of air required is: a) 14 kg 11. b) 18 kg c) 21 kg d) 10 kg Oxygen (O2) percentage measurement by volume basis can be done by using: a) ultrasonic tester b) potassium oxide probe c) copper tubes d) zirconium oxide probe 12. The percentage requirement of excess air for efficient combustion for coal is less than that of natural gas - State True or False. 13. Turndown ratio for burners is the ratio of a) air to fuel 2.1 Fuels & combustion - revised (table format) 1

Formatting page ...

Top Contributors
to this ResPaper
(answers/comments)


Shahid Kapoor

(1)

Formatting page ...

Formatting page ...

Formatting page ...

Formatting page ...

Formatting page ...

Formatting page ...

 

  Print intermediate debugging step

Show debugging info


 


Tags : Bureau of Energy Efficiency, BEE, National Productivity Council of India, NPC, Energy Audit, Certified Energy Manager, Certified Energy Auditor, EM & EA, bee papers, bee sample papers, bee books, portal for bee india, bee question bank, bee question papers with answers, bee model test papers, solved board question papers of last year, previous years solved question papers, free online solved question paper, india sample questions papers, last 10 years papers, guess sample questions papers, important questions, specimen / mock papers, 2020, 2019, 2018, 2017, 2016, 2015, 2014, 2013, 2012, 2011, 2010, 2009, 2008, 2007, 2006, 2005.  

© 2010 - 2024 ResPaper. Terms of ServiceContact Us Advertise with us

 

bee_energy chat