Trending ▼   ResFinder  

robotic arm

4 pages, 0 questions, 0 questions with responses, 0 total responses,    0    0
pleasesmoke
  
+Fave Message
 Home > pleasesmoke >

Formatting page ...

Scientech 700 Series Compact Mixed Signal Oscilloscopes Scientech Compact MSO is a unique test instrument combining a powerful Mixed Signal Oscilloscope, Protocol Analyzer, Waveform and clock Generator, Spectrum Analyzer and Data Recorder in one tiny USB powered device. It offers 10 capture channels (2 analog and 8 digital) with 100 MHz analog bandwidth, 40MSps logic speed and up to 12 bits analog resolution as well several output channels for its signal generators, triggers and external control signals. Compact MSO is fast with a frame rate up to 100 Hz driving a digital Phosphor display. It works just like a quality stand-alone scope. View waveforms, plots, spectra and more on its smooth flowing real-time screen. Even live capture logic data can be viewed this way. Alternatively large buffers support high speed one-shot capture with post-capture zoom, scrolling and measurement, or it can stream direct to disk for off-line replay and analysis. Software is included for Windows, Mac OS X or Linux. Features include mixed signal, storage and sampling Oscilloscopes, logic timing, SPI, CAN, I2C and UART packet decoders, a spectrum analyzer, X-Y phase plotter and data recorder Technical Specifications & Features Inputs Scientech 710S Scientech 710P Scientech 710U Scientech 7120U Analog Bandwidth (1) 10MHz 20 MHz 100 MHz 100 MHz 100 MHz 100 MHz Capture Channels (2) 2 Analog or 1+8 logic 2 Analog + 8 logic 2 Analog + 8 logic+4 DAQ 2 Analog or 1 + 8 logic+2 DAQ 2 Analog + 8 logic+2 DAQ 4 Analog + 8 logic+4 DAQ Input Rages (3) 1.1 V~ 5.2V 550 mV~ 5.2V 220 mV~ 5.2V 48.8 mV~ 11.8V 48.8 mV~ 11.8V 48.8 mV~ 11.8V Vertical Scaling 10 mV/Div ~ 2V/Div 5 mV/Div ~ 2V/Div 1 mV/Div ~ 2V/Div 500uV/Div ~ 5V/Div. 500uV/Div ~ 5V/Div 500uV/Div ~ 5V/Div Vertical Accuracy 3% 3% 2% 2% 2% 2% Analog Sensitivity 50mV 20mV 10mV 2mV 1mV 1mV Maximum Sensitivity (4) 5mV 2mV 1mV 200uV 50uV 100uV Scientech 7325N Scientech 7445N Technical Specifications & Features Input Filters (5) Probe Attenuation (6) Data Acquisition Inputs Protocol Inputs Analog Coupling (7) Input Impedance - UART, SPI, I2C & CAN Bus DC (Manual offset) DC (input sensing, auto offset) AC (Software switchable and auto offset) 1MW 1%, 10pF (analog), 100kW 1%, 20pF (logic) 1MW 1%, 20pF (analog), 100kW 1%, 5pF (logic) 3.3/5V CMOS (TTL compatible) Logic Input Levels Acquisition Real-Time Mixed Signal Scientech 710S Scientech 710P Scientech 710U Scientech 7120U Scientech 7325N Scientech 7445N Sub-Sampled Analog Mixed Signal Streaming Spectrum Analyzer RF Spectrum Analyzer Macro High Resolution Data Acquisition capture (via enhanced data mode) Digital Sample Rate (max) 10 MSps 20 MSps 40 MSps 40 MSps 40 MSps 40 MSps Analog Sample Rate (max) 5 MSps 10 MSps 20 MSps 40 MSps 40 MSps 40 MSps 100 MSps 500 MSps 500 MSps 2 GSps 1 GSps 100 kSps 500 kSps 50 kSps 70 kSps 70 kSps Sub-Sample Rate (max) Streaming Rate (max) - Native Resolution [8] Effective Resolution [9] Display Frame Rate (max) 8 Bits 12 Bits 10 ENOB 14 ENOB 20 Hz (50ms) Capture Buffer Sizes 12 kS, 6 kS x 2 or 6 kS x9 Timebase Range [10] 10 us/Div. ~ 2 s/Div. Timebase Accuracy 50 Hz (20ms) 8 Bits 11 ENOB 100 Hz (10ms) 12 kS, 6 kS x 2, 6 kS x 9 or 3 kS x 2+6kS x 8 10 us/Div. ~ 50 s/Div. 0.01%(100 ppm) 15 ENOB 12 ENOB 40 Hz (25ms) 64 kS x 2 64 kS x 9 512 kS x 2 or 256 kS x 2 + 512kS x 8 1ns/Div ~ 50 s/Div. 128 kS x 12 Triggers [11] Scientech 710S Scientech 710P Scientech 710U Scientech 7120U Scientech 7325N Scientech 7445N Comparator [COMP] Logic State (MASK) Sampled Analog (SALT) Logic Sequence (FUSE) Trigger Modes Hysteresis/Sensitivity Edge (Rise/Fall) & Logic 2% Edge (Rise/Fall), Level/State & Logic Edge (Rise/Fall), Level/State & Logic 2% (COMP) or variable (SALT 2% (COMP) or fixed (BAND) Trigger Filter Fast & Normal Fast, Normal & Slow (10us ~ 100ms) Cross-Trigger Operation Logic triggers analog Logic triggers analog & vice versa Logic triggers analog & vice versa 100 us to 10s (programmable) 10 us to 60s (programmable) Trigger Delay Timebase Trigger Hold-off Generators [12] Fast, Normal & Slow (10us ~ 10ms) 1 ms ~ 100ms Scientech 710S Scientech 710P 1 ms ~ 1s Scientech 710U Scientech 7120U Scientech 7325N Clock Generator (CLK) Voltage Generator (DCV) Via Replay Mode Scientech 7445N Waveform Generator (VSR) Logic Pattern Generator (LPG) Triggered One-Shot Mode Chirp/Sweep Mode Write/Pink Noise Mode Waveform Replay Mode Trigger/Sync Clocks Output Level Controls Clock frequencies (CLK) Waveform Functions (13) Frequency Range Frequency Resolution - - - 1024 sample (max) 1 kHz ~ 5 MHz 1 kHz ~ 20 MHz Sine, Ramp, Step, Exponent & loadable 2 Hz ~ 100kHz 2 Hz ~ 250kHz 1 Hz ~ 500kHz 1 Hz ~ 5 MHz 3 Digits 3 Digits below 100kHz 6 decimal digits 6 decimal digits (one shot) Sine, Ramp, Step, Exponent & loadable 50ppm, 20o to 30o (typical) Bipolar Output - 1 kHz Sine, Ramp, Step Frequency Accuracy (14) Output Level 3 Vpp 40 mVpp ~ 10 Vpp Output Impedance 100W 50W Voltage Tolerance +9V (max) +12V (max) 8 Bits 8 Bits (Multipying) Waveform Resolution - Interfaces Scientech 710S Scientech 710P Analog Interface 2x1 MW (POD) Logic Interface Scientech 710U 2 x1 MW + 4 x 100 kW (POD) 8 x 3.3/5 V 100 kW Control Interface 3.3V, 5V, GND 3.3V, 5V, GND, WavePort, Serial I/O Data Upload Speed (max) 5 Mb/s Included PC Software [15] Optional PC Software [16] Scientech 710P 2 x1 MW (BNC) +2 x 100 kW (POD) Scientech 7445N 2 x1 MW (BNC) +2 x 100 kW (POD) 12V, 5V GND, Serial I/O 12V, 5V GND, WavePort, Serial I/O Isolated USB 2.0 (USB 1.1 Compatible) USB 2.0 (USB 1.1 compatible) Scientech 710S Software (Student Edition) Scientech 7325N 8 x 3.3/5 V 100 kW (POD) PC Host Interface General Scientech 7120U Isolated ethernet 1200 kb/s Scientech 710U 1200 kb/s Scientech 7120U Scientech 7325N Scientech 7445N Scientech Virtual Instruments software Scientech Meter Scientech Logic, Meter, Chart, BitGen & Library Power Requirement 5V USB powered Operating Temperature 00C to 400C 00C to 400C or 200C to 300C (for quoted accuracy) Storage Requirements - 400C to +500C/5% to 85 % RH - 400C to +500C / 5% to 85 % RH Dimensions (W x D x H) (net) 65 x 5 x 15mm 140 x 105 x 35 mm Weight (net) 65g 310g 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 9~ 12 VDC @ 500mA (max), 2.5mm CP 12 VDC@ 1A (max), 2.5mm CP 140 x 140 x 35 mm 225 x 180 x 42 mm 432g (980g with rackmount) 1.05 Kg (1.85 Kg with rackmount) Maximum bandwidth of analog channels captured using equivalent time sampling or used with the RF spectrum analyzer with waveform amplitude captured to 10% full-scale. Scientech 710U and Scientech 710P can capture 10 channels in mixed signal mode; 2 analog + 8 logic. Scientech 710S is limited to 9 channels; 1analog+8 logic. Scientech 710U can also capture up to 6 analog channels in data acquisition mode. Scientech 710U can support 5 Input voltage ranges, Scientech 710P has 4 and Scientech 710S has 3 The differences relate to their respective input circuit designs. Maximum sensitivity refers to the smallest measurable waveform voltages in the most sensitive range with enhanced data mode enabled at frequencies below 1 MHZ. Using the spectrum analyzer signal levels below these limits can be measured. Scientech 710P and Scientech 710U include software switchable 5 MHz anti-alias filters for the analog inputs. Probe attenuation allows the inputs of the analog channels to be rescaled when attenuating probes are used. Compact MSO have DC coupled inputs. Scientech 710P and Scientech 710U include input sensing and auto offset control to allow software synthesized AC coupling. Scientech 710S support manual offset control. Native resolution is the maximum resolution of the A/D converters used. Scientech 710U has both 8 and 12 bit converters, the latter used for macro high resolution capture Effective resolution is the maximum possible resolution of captured waveforms using DSP based filtered decimation applied to the highest resolution native capture data at sample rates below 200Ksps. Timebase range includes the time scales available across all capture modes. Scientech 710P and Scientech 710U support a much wider timebase range than Scientech 710S because they support sub-sampled and mixed signal streaming capture. Up to four type of trigger; COMP= analog comparator trigger, MASK = multi-channel logic state trigger, SALT=sampled analog level trigger and fuse = fuse map logic state sequence trigger. Up to three types of waveform generator; CLK= variable mark -space clock generator, DCV=digital controlled voltage generator, VSR= variable sampled rate waveform generator. Wave-function are the function prototypes used to synthesize analog waveforms. All expect Loadable are built-in. Loadable is a user definable 512 or 1024 point wave-table which can accept an arbitrary waveform. Uncalibrated frequency accuracy is specified (as defined by the Scientech 710 reference crystal). May be calibrated to better than this if precision frequency reference is available. All Specifications are quoted on the basis that the product is used with included PC software. Some models may not be compatible with all the features provided by the software listed here. Scientech Technologies Pvt. Ltd. 94, Electronic Complex, Pardesipura, Indore- 452 010 India,

Formatting page ...

Formatting page ...

Formatting page ...

 

  Print intermediate debugging step

Show debugging info


 

 


© 2010 - 2026 ResPaper. Terms of ServiceContact Us Advertise with us

 

pleasesmoke chat